The VIPBOSS 12V 105Ah battery has a maximum continuous discharge current of 100A. That is the sustained current limit for powering connected equipment, not a target operating current. For a quick load check, multiply the battery's nominal 12.8V by the current: 12.8V × 100A equals about 1,280W before inverter, wiring, and other system losses. If your equipment can draw more than that continuously, use a larger battery bank or reduce the load rather than relying on the short-term peak rating.
What the 100A continuous rating means
A continuous discharge rating describes the current the battery can supply for ongoing operation under its specified conditions. It is different from the battery's 105Ah capacity, which describes stored charge rather than the maximum output current. The distinction between stored capacity and discharge rate is also explained in this overview of battery capacity and discharge rate.

The battery's maximum continuous discharge current is 100A. Its peak discharge rating is 350A for only 3–5 seconds, so that short-duration figure should not be used for a sustained appliance or inverter load. Check the VIPBOSS 12V 105Ah battery specifications before finalizing an installation.