An illustrative 48-watt input and 42-watt output yield 87.5 percent efficiency.
Calculate efficiency as output power divided by input power, then interpret the result using its operating conditions and measurement boundary. Efficiency curves apply to their stated input and load conditions, not every operating point.
Share
Share on X Share on Facebook Share on Pinterest

Calculate DC-DC converter efficiency by dividing output power by input power at the same operating point and multiplying by 100%. The percentage describes only the converter or system inside the measurement boundary you choose; a curve’s peak efficiency applies only under its specified conditions.

Calculate efficiency at one operating point

For DC, calculate power on each side as voltage multiplied by current:

  • Input power: input voltage × input current
  • Output power: output voltage × output current

A technician checks voltage at accessible external converter terminals.

Then use efficiency (%) = output power ÷ input power × 100. Measure or specify input and output values for the same operating point: the same converter state, input condition, and load condition. Pairing values from different loads or moments can produce a ratio that does not describe any actual operating point.

For example, suppose an illustrative converter receives 48 W and delivers 42 W at a stated load. Its efficiency is 42 ÷ 48 × 100 = 87.5%. The 6 W difference is power not delivered as output within the chosen measurement boundary. It is not automatically all converter loss unless the input and output measurements are taken at the converter’s terminals.

Define what the measurement includes

With measurements at the converter’s input and output terminals, the ratio describes converter-terminal efficiency: power delivered by the converter divided by power supplied to it. Source impedance and wiring before the input terminal sit outside that boundary. Wiring or other losses beyond the output terminal also sit outside it.

Converter-terminal and source-to-load efficiencies use different measurement boundaries.

A wider source-to-load boundary includes the portions between those measurement points. In the source-converter-load framework, source resistance and wiring can reduce system efficiency; losses included upstream or downstream therefore affect the wider ratio, even though they are not converter-internal losses. State the measurement points when reporting a percentage so readers can tell which result they are comparing. The source, converter, and load efficiency boundaries illustrate this distinction.

Read an efficiency curve at the condition you need

First check the curve’s axes and notes. Find the input-voltage condition and output-power or load condition that match the operating point you care about, then read the efficiency at that point. If the curve has separate lines for different input voltages, use the applicable line; if its conditions do not cover the point of interest, the curve does not establish efficiency there.

A peak figure is the highest stated value under its specified conditions, not a constant value across loads and input voltages. Use the curve value for the matched condition when estimating output power or losses. At that point, estimated power not delivered as output is input power multiplied by one minus efficiency as a decimal. For instance, at 90% efficiency, the difference is 10% of input power within the same measurement boundary. The efficiency ratio is output power divided by input power, expressed as a percentage.

FAQs

How do you distinguish converter-terminal efficiency from source-to-load efficiency?

Measurements at the converter’s input and output terminals describe converter-terminal efficiency, excluding source and wiring losses outside those points. A wider source-to-load measurement includes losses in the portions of the power path between its measurement points.

How should you interpret a peak efficiency value on a converter’s curve?

A peak is the highest efficiency stated for its specified input and load conditions, not a value that applies across all operating points. Use the curve value for the input-voltage and load condition of interest; if that condition is not shown, the curve does not establish efficiency there.

Can input and output readings from different loads or times be combined?

No. Calculate input and output power at the same operating point. Otherwise the ratio may not describe any actual converter condition.